Online discharge using Venturi meter
ν = f(T)
ReD2 = 4Q/(πD2ν)
K = f(ReD2, D2/D1)
A2 = (π/4) D22
hf = [Q/(KA2)]2/(2g)
h = hf/[(ρ2/ρ1) - 1]
[SI units: Q in m3/s; D in m; T in °C; h in m] [U.S. units: Q in cfs; D in ft; T in °F; h in ft]
Select:
Discharge Q :
Diameter D1 :
Diameter D2 :
Temperature T :
Ratio ρ2 /ρ1 :
OUTPUT: hρ2 = 0
hρ2
hρ1 = 0
• Venturi effect on Wikipedia
Your request was processed at 09:25:31 am on November 13th, 2024 [ 241113 09:25:31 ].