♦ Air temperature Ta (°C): 15 - 35
Changing the air temperature from 15°C to 35°C changes the evaporation from 1.05 cm d-1 to 1.20 cm d-1 [Sample data input set].
♦ Mean boundary layer resistance per unit area of vegetation rb (s m-1): 5 - 50
Changing the mean boundary layer resistance from 5 s m-1 to 50 s m-1 changes the evaporation from 1.1232 cm d-1 to 1.124 cm d-1 [Sample data input set].
♦ Mean stomatal resistance rST (s m-1): 200 - 800
Changing the mean stomatal resistance from 200 s m-1 to 800 s m-1 changes the evaporation from 0.9656 cm d-1 to 1.2404 cm d-1 [Sample data input set].
♦ Projected area of leaf per unit ground area L (dimensionless): 0 - 5
Changing the projected area of leaf per unit ground area from 0.1 to 5 changes the evaporation from 0.92 cm d-1 to 1.167 cm d-1; the evaporation from the plant canopy changes from 0.067 cm d-1 to 1.0583 cm d-1; and the evaporation from the substrate changes from 0.8536 cm d-1 to 0.1091 cm d-1 [Sample data input set].
♦ Aerodynamic resistance between canopy source height and reference level raa (s m-1):
21 - 84
Changing the aerodynamic resistance between canopy source height and reference level from 21 s m-1 to 84 s m-1 changes the evaporation from 1.1774 cm d-1 to 1.0848 cm d-1 [Sample data input set].
♦ Aerodynamic resistance between the substrate and canopy source height ras (s m-1):
64 - 256
Changing the aerodynamic resistance between the substrate and canopy source height from 64 s m-1 to 256 s m-1 changes the evaporation from 1.147 cm d-1 to 1.11 cm d-1 [Sample data input set].
♦ Surface resistance of the substrate rss (s m-1): 0 - 2000
Changing the surface resistance of the substrate from 0 s m-1 to 2000 s m-1 changes the evaporation from 1.1236 cm d-1 to 1.0902 cm d-1 [Sample data input set].
♦ Net radiation flux into the complete crop Rn (W m-2): 200 - 600
Changing the net radiation flux from 200 W m-2 to 600 W m-2 changes the evaporation from 0.7089 cm d-1 to 1.5382 cm d-1 [Sample data input set].
♦ Vapor pressure deficit at reference height D (Pa): 0 - 2000
Changing the vapor pressure deficit from 0 Pa to 2000 Pa changes the evaporation from 0.8293 cm d-1 to 1.4178 cm d-1 [Sample data input set].
♦ Extinction coefficient C (dimensionless): 0.7
Changing the extinction coefficient from 0.5 to 0.9 changes the evaporation from 1.1241 cm d-1 to 1.1233 cm d-1 [Sample data input set].
♦ Atmospheric pressure P (Pa): 100000 - 101325
Changing the atmospheric pressure from 60000 Pa to 101325 Pa changes the evaporation from 1.3427 cm d-1 to 1.1236 cm d-1 [Sample data input set].
|